Abstract

BackgroundMinimally invasive mitral valve replacement has become popular across the world. However, annular rupture and patient – prosthetic mismatch (PPM) are still problematic, particularly in the Asian population. To avoid this, a predictor model could be beneficial. Our study aimed to assess the value of mitral valve diameters measured on TTE and CT scan on predicting the actual mitral prostheses.MethodsFrom January 2018 to December 2019, a total number of 96 patients underwent minimally invasive mitral valve replacement. The association between imaging measurements and the outcome was checked by scatter plot and Pearson’s correlation coefficient. Univariable linear regression was used to build the prediction model.ResultsThe three strongest correlations for the whole population are the following features: Mean TTE diameter (0.702), mean diameter on CT lowest plane through the mitral annulus (0.679), and area-derived diameter on CT highest plane through the mitral annulus (0.665). The prosthetic size of the tissue valve group was more correlated to the calculated annulus diameters than that of the mechanical valve group. Tissue valve size predictor models based on these calculated diameters were 16.19 + 0.27 × d (r = 0.744), 12.74 + 0.44 × d (r = 0.756) and 12.79 + 0.38 × d (r = 0.730), respectively.ConclusionMitral prosthetic size could be predicted based on the mitral diameters measured on TTE and CT scan. The overall correlation coefficient varied from 0.665 (CT Scan) to 0.702 (TTE). These models performed better when applied to bioprosthesis.

Highlights

  • Mitral valve disease is a common valvular heart disease, which includes mitral stenosis, mitral regurgitation and the combination of both conditions

  • Annular rupture and patient – prosthetic mismatch (PPM) are still problematic and may affect shortterm as well as long-term outcome after mitral valve replacement, in the Asian population [2]

  • Material and methods From January 2018 to December 2019, we investigated all patients undergoing minimally invasive mitral valve replacement via a right minithoracotomy at the University Medical Center, University of Medicine and Pharmacy at Ho Chi Minh City, Viet Nam

Read more

Summary

Introduction

Mitral valve disease is a common valvular heart disease, which includes mitral stenosis, mitral regurgitation and the combination of both conditions. Annular rupture and patient – prosthetic mismatch (PPM) are still problematic and may affect shortterm as well as long-term outcome after mitral valve replacement, in the Asian population [2]. Some authors have addressed this issue before [3, 4] These articles were conducted for more than a decade and there is still a lack of consistent models. The purpose of this study is to assess the value of mitral valve diameters measured on TTE and CT scan on predicting the actual mitral prostheses. Invasive mitral valve replacement has become popular across the world. Annular rupture and patient – prosthetic mismatch (PPM) are still problematic, in the Asian population. Our study aimed to assess the value of mitral valve diameters measured on TTE and CT scan on predicting the actual mitral prostheses

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.