Abstract

Microbiologically influenced corrosion (MIC) is becoming a knotty problem for transmission pipelines. Developing MIC mitigation strategies for pipelines is increasingly urgent. In this study, MIC resistance against Pseudomonas aeruginosa of the X65 pipeline steels with (X65Cu) and without (X65) Cu addition was comparatively studied by electrochemical measurements and surface observation. Experimental results demonstrated that the corrosion rate of X65Cu steel was lower than that of X65 steel no matter in sterile or bacteria-containing media. Cu addition is helpful to the formation of the rust layer in the sterile medium. Surface observation showed that X65Cu steel exhibited a better MIC resistance against P. aeruginosa than that of X65 steel. Cu ions released from the X65Cu steel could effectively kill the P. aeruginosa attached on the steel surface, thus evidently decreased the pit depth and diameter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.