Abstract

Hydrogen is a promising alternative fuel, however, its flammable nature raises safety concerns. In case of accidental hydrogen release inside an enclosure a common mitigation measure is natural ventilation. The enclosure is likely to be exposed to wind and thus the wind effect on the ventilation should be thoroughly investigated. In the present study, we address the hydrogen release into a single-vented facility with wind blowing onto the opposite side of the vent wall. Wind can either assist or oppose the ventilation dependent on the vent configuration and the wind direction. Previous study has shown that wind blowing onto the opposite side of the vent wall in single-vented enclosure inhibits the exchange flow rate through the vent. Therefore, this study aims in removing this disrupting wind effect by considering different flow deflectors around the vent. A flow deflector is proposed which drastically enhances the ventilation and eliminates the negative effect of wind. For this deflector a parametric analysis of its length is also carried out. The analysis shows that a size equal to the vent height is considered a good compromise between efficient ventilation and practical considerations. For the analysis, CFD simulations were performed using the CFD code ADREA-HF earlier validated against several similar cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.