Abstract

Internal mist/steam blade cooling technology has been considered for the future generation of Advanced Turbine Systems (ATS). Fine water droplets of about 5 μm were carried by steam through a single slot jet onto a heated target surface in a confined channel. Experiments covered Reynolds numbers from 7500 to 25,000 and heat fluxes from 3 to 21 kW/m2. The experimental results indicate that the cooling is enhanced significantly near the stagnation point by the mist, decreasing to a negligible level at a distance of six jet widths from the stagnation region. Up to 200 percent heat transfer enhancement at the stagnation point was achieved by injecting only ∼1.5 percent of mist. The investigation has focused on the effects of wall temperature, mist concentration, and Reynolds number.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.