Abstract

At a machining center used to produce transmission parts, aerosol instrumentation was used to quantitatively study mist generation and to evaluate the performance of an air cleaner for controlling the mist. This machining center drilled and tapped holes at rotational speeds of 1000 to 3000 rpm. During most machining operations, the metal-working fluid (MWF) was flooded over the part. To facilitate metal chip removal during some operations, MWF was pumped through the orifices in some tools at a pressure of 800 psi. These machining operations were performed in a nearly complete enclosure that was exhausted to an air cleaner at a flow rate of 1.1 m3/sec (2400 ft3/m). Although the use of high-pressure MWF increased the mist concentration by about 200%, it did not affect the mist size distribution. The observed penetration through the air cleaner appeared to be mostly consistent with the manufacturer's specifications on the air cleaner's filters. During the testing, MWF was observed to accumulate in the bottom of the filter housing and may have been reentrained due to air motion or mechanical vibration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.