Abstract

The trace (A), maximum average prediction variance (G), and integrated average prediction variance (V) criteria are experimental design evaluation criteria, which are based on precision of estimates of parameters and responses. Central Composite Designs(CCD) conducted within a split-plot structure (split-plot CCDs) consists of factorial (𝑓), whole-plot axial (𝛼), subplot axial (𝛽), and center (𝑐) points, each of which play different role in model estimation. This work studies relative A-, G- and V-efficiency losses due to missing pairs of observations in split-plot CCDs under different ratios (d) of whole-plot and sub-plot error variances. Three candidate designs of different sizes were considered and for each of the criteria, relative efficiency functions were formulated and used to investigate the efficiency of each of the designs when some observations were missing relative to the full one. Maximum A-efficiency losses of 19.1, 10.6, and 15.7% were observed at 𝑑 = 0.5, due to missing pairs 𝑓𝑓, 𝛽𝛽, and 𝑓𝛽, respectively, indicating a negative effect on the precision of estimates of model parameters of these designs. However, missing observations of the pairs- 𝑐𝑐, 𝛼𝛼, 𝛼𝑐, 𝑓𝑐, and 𝑓𝛼 did not exhibit any negative effect on these designs' relative A-efficiency. Maximum G- and Vefficiency losses of 10.1,16.1,0.1% and 0.1, 1.1, 0.2%, were observed, respectively, at 𝑑 = 0.5, when the pairs- 𝑓𝑓, 𝛽𝛽, 𝑐𝑐, were missing, indicating a significant increase in the designs' maximum and average variances of prediction. In all, the efficiency losses become insignificant as d increases. Thus, the study has identified the positive impact of correlated observations on efficiency of experimental designs.
 Keywords: Missing Observations, Efficiency Loss, Prediction variance

Highlights

  • Industrial, manufacturing, and engineering and central composite design (CCD)

  • A CCD with a splitphysical sciences research projects require plot structure consists of four different categories of experimentation to uncover relationships that exist between design variables and the responses of interest

  • Throughout response surface methodology (RSM) literature, little or no attention has been given to the effect of missing observations on

Read more

Summary

Introduction

Industrial, manufacturing, and engineering and central composite design (CCD). A CCD with a splitphysical sciences research projects require plot structure consists of four different categories of experimentation to uncover relationships that exist between design variables and the responses of interest.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.