Abstract

Background and Objectives: Here, we performed a descriptive analysis of Down syndrome (DS) cases that were misdiagnosed and/or false-negative diagnosed after first trimester traditional screening via risk evaluation using ultrasound, biochemical markers, and different software programs. Our objective was to demonstrate the clear need to improve the application of prenatal DS screening programs using standardized ultrasound measurements, accurate pregnancy dating, analytical immunoassay performance, and properly selected medians. Materials and Methods: We performed a database search for the period 2010–2015 to analyze DS cases that were false-negative diagnosed after the first trimester of pregnancy, before the introduction of cell free fetal DNA-based tests by Romanian laboratories in 2015. First-trimester screening was performed using two software programs for prenatal DS risk calculation: Astraia and Prisca. The rationale for using both software programs was to assess the full risk using the maternal age combined test (based on nuchal translucency thickness, nasal bone, ductus venosus flow, tricuspid flow, free beta-human chorionic gonadotropin level, and serum pregnancy-associated plasma protein-A) and, in some cases, the triple test. Results: We identified seven DS cases that exhibited low risk for trisomy 21, and 6540 cases with a low risk for trisomy 21 and euploid fetus in the first trimester. Using Astraia software, 14 cases were diagnosed, and three cases were missed after risk calculation. Using Prisca software, four cases were missed. Additionally, one neonate had a missed prenatal diagnosis of atrio-ventricular canal defect. Conclusion: In Romania, the evaluation of DS risk depends on patient choice (without knowing the accuracy of the utilized tests) and on the operators’ skills. Both Astraia and Prisca software were developed by experts, who can prove their performance in DS screening. However, even in an ideal situation, false-negative results are possible. The application of first and second-trimester combined screening based on biochemical markers could be improved by the implementation of standardized protocols, professional guidelines for test application, and audit control.

Highlights

  • Down syndrome (DS; trisomy 21) is caused by an additional chromosome 21, and is the most heavily studied autosomal trisomy

  • The accuracy of first-trimester DS screening tests has been demonstrated in large prospective international studies, with a combined test showing over 90% detection of T21, and a false-positive rate of 3–5% [9,10,11,12]

  • The stable number of newborns with DS in Romania over the last 20 years justifies the need for appropriate training for all doctors who perform screening ultrasounds, the use of biochemical markers in screening, as well as an audit of DS screening in the general population

Read more

Summary

Introduction

Down syndrome (DS; trisomy 21) is caused by an additional chromosome 21, and is the most heavily studied autosomal trisomy. We performed a descriptive analysis of Down syndrome (DS) cases that were misdiagnosed and/or false-negative diagnosed after first trimester traditional screening via risk evaluation using ultrasound, biochemical markers, and different software programs. Materials and Methods: We performed a database search for the period 2010–2015 to analyze DS cases that were false-negative diagnosed after the first trimester of pregnancy, before the introduction of cell free fetal DNA-based tests by Romanian laboratories in 2015. First-trimester screening was performed using two software programs for prenatal DS risk calculation: Astraia and Prisca. Conclusion: In Romania, the evaluation of DS risk depends on patient choice (without knowing the accuracy of the utilized tests) and on the operators’ skills Both Astraia and Prisca software were developed by experts, who can prove their performance in DS screening. The application of first and second-trimester combined screening based on biochemical markers could be improved by the implementation of standardized protocols, professional guidelines for test application, and audit control

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.