Abstract

BackgroundThe left ventricular (LV) vent is commonly inserted via the right superior pulmonary vein (RSPV) and directed toward the LV cavity through the mitral valve. We report a rare case in which the tip of the LV vent was misplaced into the aortic root across the aortic valve.Case presentationAn 88-year-old man was scheduled to undergo the Bentall procedure. After initiation of cardiopulmonary bypass, the LV vent was inserted via the RSPV. Anterograde cardioplegia was administered via the aortic root cannula after the ascending aorta was cross-clamped. The electrocardiogram did not result in complete cardiac arrest, even after delivery of two-thirds of the planned dose. A transesophageal echocardiographic examination showed that the tip of the LV vent was misplaced into the aortic root across the aortic valve.ConclusionsIt is important to confirm the tip position by transesophageal echocardiography to prevent severe complications associated with the LV vent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.