Abstract

BackgroundThe question of rod bending is essential during posterior lumbar fusion. The role of posterior instrumentation during spinal surgery remains to be defined. Despite an appropriate bending, a mismatch between rod lordosis and lumbar lordosis can occur. There is no study on the link between rod bending and lordosis. The purpose of this study was to evaluate parameters that explain the mismatch between lumbar lordosis and rod bending in lumbar surgery using polyaxial screws. HypothesisRadiological parameters explain the mismatch between the rod and the lordosis. MethodsThis study was monocentric, retrospective, descriptive and analytic. All patients with posterior L3L5 fusion in an university-affiliated hospital in 2017 were included. Patients with past surgical history of anterior fusion on the levels L3L5, Coronal malalignment with a Cobb angle superior to 5°, the use of dynamic fixation systems were excluded. We measured on immediate post-operative standing profile x-ray: pelvic incidency, lumbar lordosis, lordosis of the instrumented segment, the distance between posterior wall and rod (EcarT) which reflect how homogeneously the screws are put in depth, the angle between screw and rod (thetaMA), the angle between screw and superior endplate (lambdaMA), the rod lordosis. Univariate and multivariate analysis were conducted to see if there was a link between all those parameters and the mismatch: vertebral lordosis-rod lordosis. ResultsA total of 74 patients were included, mean age was 67. Eighteen were 360° fusion and 56 were postero-lateral fusions. There was no statistical association between demographic data, pelvic parameters, use of interbody devices and the mismatch. There was a statistical association between thetaMA, lambdaMA, EcarT and the mismatch (P<0,0001). A multivariate linear regression model was developed to create a new index: Mismatch analysis index. ConclusionOur study is the first on the link between rod bending and lumbar lordosis. Three radiologic factors are involved in not obtaining the planned lordosis in short lumbar fusion with polyaxial screws. Two factors depend on the way the surgeon positions screw parallel to the superior vertebral endplate(lambdaMA), and with a homogeneous depth (EcarT). And the last factor: ThetaMA is depending on the surgical technique (compression on screws, osteotomies, monoaxial screws, use of interbody devices). Level of evidenceIV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.