Abstract
A number of publications have claimed that Mobitz type II atrioventricular block (AVB) may occur during sleep. None of the reports defined type II AVB and representative electrocardiograms were either misinterpreted or missing. Relatively benign Wenckebach type I AVB is often misdiagnosed as Mobitz type II which is an indication for a pacemaker. Review of the published reports indicates that Mobitz type II AVB does not occur during sleep when it is absent in the awake state. Conclusion: There is no proof that sleep is associated with Mobitz type II AVB.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.