Abstract
A graphical method was used to assess the effect on pupil shape and circumference of various flexible iris hook malpositions. Results confirmed that all hook malpositions necessitate increased pupil stretching to create space to perform a capsulorhexis of a given diameter. This method also confirmed that the addition of a fifth hook to create a pentagonal pupil reduces pupil stretching by 17%. A simple method of marking the limbus before hook insertion to ensure equidistant hook separation and thus minimize pupil stretching is suggested.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.