Abstract

Natural ventilation, as a medium for air exchange between the indoor and outdoor environment, is known for its functions of providing outdoor ‘fresh’ air and removing indoor air pollutants. In this study, the minimum outdoor air ventilation rate required to maintain radon concentration at an acceptable level was determined. Radon and air change per hour (ac/h) were measured simultaneously and systematically in a concrete high rise residential building (denoted as SP). The radon level and radon emanation rate of SP were about 435 Bq/m3 and 72.48 Bq/m2/h respectively. Modelling results showed that, for the action level of 200 Bq/m3(according to WHO) and 150 Bq/m3 (HKEPD), the outdoor air supply in SP should exceed 0.61 ac/h and 0.88 ac/h respectively. The average background infiltration in SP was 0.36 ac/h and a window-type air-conditioner can deliver 0.74 ac/h. In situ measurements showed that background infiltration in SP was inadequate to suppress indoor radon below 200 Bq/m3 but a well vented air-conditioner was sufficient to achieve that level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.