Abstract

In DC-DC converters like Dual Active Bridge (DAB) and Dual Active Half Bridge (DAHB) where leakage inductance also acts like power transfer inductance, it is important to have optimum leakage inductance, especially in high frequency applications. High value of leakage inductance result in high RMS current through transformer with higher conduction losses in transformer and switches, whereas, low value of leakage inductance result in loss of Zero Voltage Switching (ZVS) turn-on at lower power level with higher switching losses. This paper presents analytical derivation of minimum leakage inductance and dead-time for ZVS turn-on of switches in Current Source Voltage Source (CSVS) type of Dual Active Half Bridge (DAHB) DC/DC Converter which can be used to design optimal leakage inductance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.