Abstract

To the Editor: —We read with interest the recently published case reports by Loubert et al. 1and Zetlaoui et al. 2regarding suspected inadvertent intravascular injection of local anesthetic (LA) and LA toxicity during ultrasound-guided axillary brachial plexus blockade. While ultrasound likely reduces the risk of accidental vascular puncture compared with “blind” peripheral nerve stimulation,3these two case reports demonstrate that the risk of intravascular injection persists despite ultrasound guidance.1,2In 2006 and 2007 at the Toronto Western Hospital, we performed 1,797 ultrasound-guided brachial plexus blocks without any sign or symptom of LA toxicity. Good fortune notwithstanding, there are several important principles that merit thoughtful consideration to improve detection of accidental intravascular injection and possibly prevent LA toxicity during ultrasound-guided peripheral nerve blockade. We believe that the most reliable feature during real-time ultrasound imaging indicative of intravascular injection is the failure to visualize a hypoechoic fluid bolus on the ultrasound monitor during and/or after injection of as little as 1 ml of injectate. Indeed, we customarily initiate LA injection with a 1-ml bolus to exclude intravascular or intraneural4,5needle tip placement before proceeding with 5-ml increments of injectate. Visualization of the needle tip does not preclude intravascular injection per se ; it is the real-time observation of hypoechoic fluid causing tissue dispersion that most consistently excludes intravascular injection. The absence of a discernible extraneural hypoechoic fluid bolus on the ultrasound monitor means that either the needle tip is intravascular or the plane of imaging is inaccurate.We are also hesitant to recommend the use of ultrasound for perivascular block techniques as described by Loubert et al. 1Rather, we contend that perineural LA deposition is the safest application of ultrasound technology. There can be multiple veins traveling alongside landmark pulsatile arteries, especially in the axilla. Veins are exquisitely collapsible with even the slightest amount of pressure applied by the transducer to the skin, and can therefore vanish from sonographic view, fooling even the most experienced providers, as demonstrated by these two recent case reports.1,2We therefore use systematic scanning of the intended block site before needle insertion. Our systematic sonographic survey includes sliding the transducer distally and proximally to trace the target nerve along its expected course and examine the surrounding vasculature and tissues. Scanning is performed with varying degrees of pressure, with and without the use of color Doppler, to identify any hazards that may cross the planned trajectory of the needle. In addition, applying pulse wave Doppler over a nearby vessel during perineural injection may help to detect inadvertent intravascular injection by the characteristic high-pitch sound of turbulent flow associated with a sudden rush of fluid. Finally, however contentious,6we strongly believe that patients undergoing ultrasound-guided peripheral nerve blockade should remain awake with judicious sedation so that signs and symptoms of LA toxicity can be recognized, communicated, and treated immediately upon onset.*Toronto Western Hospital, University Health Network, University of Toronto, Toronto, Ontario, Canada. richard.brull@uhn.on.ca

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.