Abstract

To present a novel, semi-closed, surgical technique for coxofemoral luxation stabilisation using a transarticular toggle rod. Cadaveric study. Craniodorsal luxation was generated by transecting the ligamentum teres in 12 coxofemoral joints and was then reduced using a closed technique. Anteversion and inclination angles were measured using fluoroscopic projections. An arthroscope was inserted through a bone tunnel drilled from the third trochanter through the femoral neck. Following retraction of the arthroscope, a hole was drilled through the acetabular fossa via the femoral bone tunnel. A standard Arthrex® TightRope toggle button was pushed through the femoral bone tunnel into the acetabular fossa hole and tied over the oval metallic button above the third trochanter site. The exit point of the drill hole over the femoral head and that in the acetabular fossa were evaluated by surgical exposure of the coxofemoral articular surfaces. The TightRope entrance point into the acetabular fossa was accurate in all joints, with a mean distance from the acetabular fossa centre of 0·06 ±0·1 mm. The measured distance of the TightRope exit point from the femoral head to the fovea capitis was 2·04 ±1·7 mm. Femoral head cartilage damage was detected in nine of 12 joints. Closed reduction and stabilisation of coxofemoral luxations can be achieved using this minimally invasive technique. Refinements to the technique may be needed for its application in clinical cases due to relative high incidence of femoral head cartilage damage.