Abstract

A temperature-insensitive miniaturized all-fiber Fabry–Perot interferometer strain sensor was proposed and experimentally studied. This sensor with an air cavity was made by splicing a short section of hollow-core fiber with two standard single mode fibers. The experimental results showed that these sensors have an fringe contrast exceeding 22 and 13 dB for the air cavity with a length of 167.08 and 557.11 μm, and its reflection spectrum shifts linearly to long wavelength by increasing the strain from 0 to 3000 μe with a strain sensitivity of 1.8 and 1.7 pm/μe, respectively. This strain sensor also showed good repeatability and long time stability, while its temperature sensitivity was only about 0.95 pm/°C in the range of 0°C–180°C for the 557.11 μm air cavity, so there is less strain–temperature cross-sensitivity. Moreover, this sensor was easy to be fabricated and there was no requirement for chemical etching, careful cleaving, and special fusion. It may be potentially used for strain sensing applications with high resolution and miniaturized size. © 2016 Wiley Periodicals, Inc. Microwave Opt Technol Lett 58:1510–1514, 2016

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.