Abstract
This paper proposes a multi-input, multi-output (MIMO) nonlinear system identification (SI) of civil structures equipped with magnetorheological (MR) dampers. The nonlinear SI model is developed through the integration of multiple MIMO autoregressive exogenous (ARX) input models, Takagi-Sugeno (TS) fuzzy model, weighted linear least squares, fuzzy C-means and subtractive clustering algorithms. To demonstrate the effectiveness of the MIMO ARX-TS fuzzy model, a seismically excited three-story building equipped with an MR damper is investigated: Parameters of the premise and consequent parts for the proposed model are represented in detail and comparison between the original data and identified one is given. It is shown from the simulation that the proposed nonlinear MIMO ARX-TS fuzzy identification algorithm is effective in estimating nonlinear behavior of a seismically excited building-MR damper system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.