Abstract

We have developed a highly efficient microfluidic sample preconcentration device based on the electrokinetic trapping mechanism enabled by nanofluidic filters. The device, fabricated by standard photolithography and etching techniques, generates an extended space charge region within a microchannel, which was used to both collect and trap the molecules efficiently. The electrokinetic trapping and collection can be maintained for several hours, and concentration factors as high as 10(6)-10(8) have been demonstrated. This device could be useful in various bioanalysis microsystems, due to its simplicity, performance, robustness, and integrabilty to other separation and detection systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.