Abstract

BackgroundTo restore rotation center exactly in revision hip arthroplasty is technically challenging, especially in Paprosky type III. The technical difficulty is attributable to the complicated acetabular bone defect. In this study, we discussed the method of restoring rotation center in revision hip arthroplasty and reported the clinical and radiological outcome of mid-term and long-term follow-up.MethodsThis study retrospectively reviewed 45 patients (48 hips) who underwent revision hip arthroplasty, in which 35 cases (35 hips) were available for complete follow-up data. During the operation, the acetabular bone defect was reconstructed by impaction morselized bone graft, and the hip rotation center was restored by using remnant Harris fossa and acetabular notches as the marks. The clinical outcome was assessed using the Harris hip score. Pelvis plain x-ray was used to assess implant migration, stability of implants, and incorporation of the bone graft to host bone.ResultThe average follow-up duration was 97.60 months (range 72–168 months). The average Harris hip score improved from 29.54 ± 10.87 preoperatively to 83.77 ± 5.78 at the last follow-up. The vertical distance of hip rotation center measured on pelvis x-ray was restored to normal, with the mean distance (15.24 ± 1.31) mm (range 12.4~17.3 mm). The mean loss of vertical distance of hip rotation center was (2.21 ± 0.72) mm (range 1.1 ~ 5.3 mm) at the last follow-up.ConclusionSatisfactory clinical and radiological outcome can be obtained through restoring hip rotation center by using remnant Harris fossa and acetabular notches as the anatomical marks in revision hip arthroplasty.

Highlights

  • To restore rotation center exactly in revision hip arthroplasty is technically challenging, especially in Paprosky type III

  • It has been widely recognized that restoring the rotation center in revision hip surgery is beneficial to balance the stress distribution of hip joint, reduce the wear of prosthesis, and extend the survivorship of prosthesis [1, 2]

  • The purpose of this study is to report a practical and reliable technique to restore the rotation center in revision hip arthroplasty as well as mid-term and long-term result of clinical and radiological follow-up

Read more

Summary

Introduction

To restore rotation center exactly in revision hip arthroplasty is technically challenging, especially in Paprosky type III. The technical difficulty is attributable to the complicated acetabular bone defect. We discussed the method of restoring rotation center in revision hip arthroplasty and reported the clinical and radiological outcome of mid-term and long-term follow-up. There has been an increasing interest in restoring the rotation center in revision hip arthroplasty for patients with complicated acetabular bone defect [3]. many methods concern. The purpose of this study is to report a practical and reliable technique to restore the rotation center in revision hip arthroplasty as well as mid-term and long-term result of clinical and radiological follow-up

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call