Abstract
Fracture-dislocation of the midfoot with collapse of the longitudinal arch is common in patients with neuropathic arthropathy of the foot. In this study, we describe a technique of midfoot arthrodesis with use of intramedullary axial screw fixation and review the results and complications following use of this technique. A retrospective study of twenty-two patients who had undergone surgical reconstruction and arthrodesis to treat Charcot midfoot deformity was performed. Bone resection and/or osteotomy were required to reduce deformity. Axially placed intramedullary screws, inserted either antegrade or retrograde across the arthrodesis sites, were used to restore the longitudinal arch. Radiographic measurements were recorded preoperatively, immediately postoperatively, and at the time of the last follow-up and were analyzed in order to assess the amount and maintenance of correction. Patients were evaluated clinically and radiographically at an average of fifty-two months. Complete osseous union was achieved in sixteen of the twenty-two patients, at an average of 5.8 months. There were five partial unions in which a single joint did not unite in an otherwise stable foot. There was one nonunion, with recurrence of deformity. All patients returned to an independent functional ambulatory status within 9.5 months. Weight-bearing radiographs showed the talar-first metatarsal angle, the talar declination angle, and the calcaneal-fifth metatarsal angle to have improved significantly and to have been corrected to nearly normal values by the surgery. All measurements remained significantly improved, as compared with the preoperative values, at the time of final follow-up. There were no recurrent dislocations. Three patients had a recurrent plantar ulcer at the metatarsophalangeal joint that required additional surgery. There were eight cases of hardware failure. Open reduction and arthrodesis with use of multiple axially placed intramedullary screws for the surgical correction of neuropathic midfoot collapse provides a reliable stable construct to achieve and maintain correction of the deformity.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.