Abstract

Middle ear surgery techniques have enabled to improve hearing destroyed by a disease. Despite huge improvement in instrumentation and techniques the results of hearing improvement surgery are still difficult to predict. This paper presents the results of vibrations measurements in a human middle ear obtained at the Medical University of Lublin. Vibrations of the stapes in the case of the intact ossicular chain, after cement incus rebuilding and incus interpositions are compared each other. In this aim a new approach of ossicles vibrations observation is introduced in order to complete information obtained from classical approach which bases on the transfer function. Measurements of ossicular chain vibrations are performed on fresh human temporal bone specimen using the laser doppler vibrometer. Next, after classical research, the extended analysis with the recurrence plots technique is performed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.