Abstract
BackgroundFemoral stem subsidence is a known cause of early implant failure, increasing the risk for aseptic loosening and periprosthetic fracture. Overall survivorship and subsidence in a novel porous tantalum-coated femoral prosthesis have not been well-studied. MethodsConsecutive patients undergoing primary total hip arthroplasty with a porous tantalum-coated femoral prosthesis between January 2008 and January 2015 with minimum 5-year follow-up were included. Clinical and radiographic data were obtained from hospital and office records. Multivariate logistic regression analyses were used to determine predictors of subsidence and clinical outcomes. Kaplan-Meier survivorship curves were performed to illustrate primary failure endpoints of (1) all-cause revision and (2) femoral prosthesis revision. ResultsA total of 398 patients with a mean (±standard deviation) age of 61.0 ± 11.5 years, body mass index (BMI) 32.8 ± 8.0 kg/m2, and follow-up of 6.9 (range 5.0-11.2 years) were included. Survivorship at 5 years was 94.9% for all-cause revision and 98.0% for femoral component revision. Average subsidence was 1.8 ± 1.3 mm (range 0-15.5), with 8.1% patients experiencing subsidence >5 mm. Statistically significant mean improvements were observed at latest follow-up in the Hip Disability and Osteoarthritis Outcome Score Joint Replacement (40.6 ± 11.5 vs 85.2 ± 10.1, P < .001), Harris Hip Score (38.0 ± 12.0 vs 79.5 ± 12.8, P < .001), and hip flexion (92.8° ± 15.3° vs 103.3° ± 10.3°, P < .001). Multivariate logistic regression analyses revealed that greater BMI (odds ratio [OR] 1.17, P < .001), non-white/Caucasian race (OR 2.0, P = .036), and female gender (OR 2.4; P = .005) conferred a higher likelihood of subsidence >3 mm. BMI was a statistically significant and independent predictor of subsidence >5 mm (OR 1.25, P < .001) and subsidence >7 mm (OR 1.25, P < .001). ConclusionThe trabecular metal taper femoral prosthesis conferred excellent clinical outcome improvement and survivorship. Increasing BMI was independently associated with an increased risk of subsidence in these patients and caution is recommended in utilizing this implant in obese, morbidly obese, and super morbidly obese populations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.