Abstract

To explore the mid-term effectiveness of combined knee extensor mechanism realignment with bone anchor for recurrent patella dislocation. Between August 2017 and May 2019, 21 patients with recurrent patella dislocation underwent combined knee extensor mechanism realigament with bone anchor and followed up more than 3 years. There were 8 males and 13 females with an average age of 19.4 years (range, 13-26 years). All 21 patients had a history of recurrent patellar dislocation for 2-5 times (median, 3 times), and the disease duration was 1-16 years (mean, 5 years). The preoperative Lysholm score was 67.5±6.3 and the Kujula score was 64.1±7.0. The defect of meniscus, anterior and posterior cruciate ligaments, and medial and lateral collateral ligaments were excluded by MRI examination; CT examination showed that the tibial tuberosity-trochlear groove distance was 2.05-2.56 cm, with an average of 2.16 cm; X-ray examination showed that lower limb force line was abnormal. The effectiveness were evaluated by Lysholm score and Kujula score before operation and at 3 years after operation, and Insall evaluation standard at 3 years after operation. All the incisions healed by first intention, and there was no surgical complication such as lower extremity deep vein thrombosis, incision infection, and nerve injury. All 21 patients were followed up 3.0-3.5 years, with an average of 3.2 years. Anteroposterior and lateral X-ray films of the knee joint at 3 years after operation showed that the position of the patella was normal, and the axial X-ray films of the patella (30°, 60°, 90°) showed that the patellofemoral joint had a good relationship. During the follow-up, there was no anchor drop or fracture, no obvious pseudarthrosis formation, and no epiphyseal injury in the minor patients. The Lysholm score was 91.5±7.1 and the Kujula score was 88.1±7.6 at 3 years after operation, which were significantly improved when compared with those before operation ( t=11.57, P=0.00; t=12.78, P=0.00). According to the Insall evaluation criteria, 12 cases were excellent, 4 cases were good, 4 cases were fair, and 1 case was poor, with an excellent and good rate of 76.2%. Combined knee extensor mechanism realignment with bone anchor is a simple and reliable way to treat the recurrent patella dislocation, with a satisfactory mid-term effectiveness and less complications; however, its long-term effectiveness needs further follow-up.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.