Abstract

The effects of ultrasonic power, liquid-solid ratio and time on the vanadium leaching rate, surface tension, and contact angle were studied in this experiment. The optimum process conditions were determined: 10g for the sample; 1000w for ultrasonic power; 4:1 (mL/g) for liquid-solid ratio; 90 min for leaching time. The leaching rate of vanadium can reach 92.22%. The leaching rate of vanadium can be much improved with same time, when ultrasonic was used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.