A correlation reflectometer in 8-mm wavelength range has been constructed and installed on CASTOR tokamak. The reflectometer can operate on three fixed frequencies (29, 33, and 35 GHz). This is universal correlation sine-cosine reflectometer, which can work in poloidal or toroidal correlation regime and in ordinary mode (O-mode) and/or extraordinary mode (X-mode). A computational method of a direct evaluation of the phase fluctuations as well as absolute value of the phase from sine-cosine data has been developed. Using this method the relative plasma density fluctuations in the CASTOR core plasma has been determined in the range of few percent under assumption of parabolic density distribution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.