Abstract

IntroductionHalf of all hypertensive individuals have inadequately-controlled BP because monitoring methods are ineffective. This single centre study examined consecutive subjects undergoing 24 hour BP measurements for clinic and ambulatory BP levels, and for end-organ damage (retinal microvascular abnormalities and left ventricular hypertrophy, LVH, > 1.1 cm). Retinal images were graded for microvascular retinopathy (Wong and Mitchell classification), and vessel calibre using a semiautomated method. Features were compared using chi-squared, Fisher’s exact or the student’s t test.MethodsOne hundred and thirty-one individuals (59 male, 45.0%, mean age 61.7 ± 14.5 years) were studied. Ninety-nine (76.2%) had a clinic BP ≥ 140/90 mm Hg, 84 (64.6%) had a mean awake systolic BP ≥ 135 mm Hg, 100 (76.9%) had a mean sleeping systolic BP ≥ 120 mm Hg, and 100 (76.2%) had abnormal nocturnal BP dipping patterns. Sixty-nine individuals had undergone echocardiography and 23 (33.3%) had LVH.ResultsAll participants had a mild (88.5%) or moderate (11.5%) microvascular retinopathy. Moderate microvascular retinopathy was found in 86.7% of those with a mean awake systolic BP ≥135 mm Hg (p = 0.058) but was not associated with other abnormal BP measurements, abnormal dipping patterns or LVH. However retinal arteriole calibre was reduced in subjects with a mean 24 hour awake systolic BP ≥ 135 mm Hg (p = 0.05). Retinal arteriole calibre was smaller in subjects with LVH (128.1 ± 13.5 μm compared with 137.6 ± 14.1 μm in normals, p = 0.014). Venular calibre was also less in subjects with LVH (185.4 ± 24.6 μm compared with 203.0 ± 27.2 μm in normals, p = 0.016). Arteriole narrowing predicted an increased risk of LVH (AUC 0.69, 95%CI 0.55 to 0.83) that was comparable with 24 hour systolic BP ≥130 mm Hg (AUC 0.68, 95%CI 0.53 to 0.82) and mean awake systolic BP ≥135 mm Hg (AUC 0.68, 95%CI 0.54 to 0.83).ConclusionsThis study suggests that retinal arteriole narrowing may be equally accurate in predicting LVH as any clinic or ambulatory BP measurement. The convenience and accuracy of microvascular calibre measurement mean that it should be investigated further for a role in routine hypertension assessment and monitoring.

Highlights

  • Half of all hypertensive individuals have inadequately-controlled BP because monitoring methods are ineffective

  • Moderate microvascular retinopathy was found in 86.7% of those with a mean awake systolic BP 135 mm Hg (p = 0.058) but was not associated with other abnormal BP measurements, abnormal dipping patterns or left ventricular hypertrophy (LVH)

  • Retinal arteriole calibre was smaller in subjects with LVH (128.1 ± 13.5 μm compared with 137.6 ± 14.1 μm in normals, p = 0.014)

Read more

Summary

Introduction

Half of all hypertensive individuals have inadequately-controlled BP because monitoring methods are ineffective. This single centre study examined consecutive subjects undergoing 24 hour BP measurements for clinic and ambulatory BP levels, and for end-organ damage (retinal microvascular abnormalities and left ventricular hypertrophy, LVH, > 1.1 cm). Retinal images were graded for microvascular retinopathy (Wong and Mitchell classification), and vessel calibre using a semiautomated method. Features were compared using chi-squared, Fisher’s exact or the student’s t test

Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.