Abstract

Microneutralization tests for detection of antibody in bovine serum to three bovine viruses are described. The Madin-Darby bovine kidney cell line was used with parainfluenza 3 virus (PI 3), whereas serially cultivated bovine embryonic kidney cells were used for infectious bovine rhinotracheitis virus and bovine virus diarrhea virus. Comparison of micro-hemagglutination-inhibition (HI) with micro-serum-neutralization (SN) tests for PI 3 showed the SN test to be more sensitive, more specific, and therefore more useful than the HI test for detecting antibody. Although the effect of trypsin-periodate treatment of serum was to reduce the HI titer of numerous sera by a twofold dilution, sufficient evidence could not be found to indicate that nonspecific HI inhibitors to PI 3 are present in bovine sera.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.