Abstract

Magnesium alloys are potential biodegradable materials for biomedical application. But their poor corrosion resistance may result in premature failure of implants. In this study, to solve this problem, Ca-P coatings were prepared on ZK60 magnesium alloy by a simple chemical conversion process and heat treatment. Surface characterization showed that a flake-like Dicalcium phosphate dihydrate (DCPD) (CaHPO₄·2H₂O) coating was formed on ZK60 alloy by the chemical conversion process. DCPD transformed into Dicalcium phosphate anhydrous (DCPa) (CaHPO₄) and Ca₂P₂O₇ after heat treatment. Results of potentiodynamic polarization showed the corrosion potential of ZK60 was increased from -1666 mV to -1566 mV with DCPD coating, while -1515 mV was obtained after heat treatment. The corrosion current density of ZK60 was measured to be reduced from 35 µA/cm² to 3.5 µA/cm² with DCPD coating, while a further reduction to 1 µA/cm² was observed after heat treatment. This indicated that the coatings improved the substrate corrosion resistance significantly, and apparently, the heat-treated coating had a higher corrosion resistance. Immersion test demonstrated that both the coatings could provide protection for the substrate and the heat-treated coating could induce deposition of bone-like apatite. Cytotoxicity evaluation revealed that none of the samples induced toxicity to L-929 cells after 1- and 3-day culture. The cytocompatibility of ZK60 was improved by the coatings, with the following sequence: uncoated ZK60 < DCPD-coated ZK60 < heat-treated coating.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call