Abstract
The aim of this study is to investigate the effect of applying various welding current parameters of shielded metal arc welding (SMAW) on microstructure and the hardness of the hardfacing overlays. The investigation was performed on a 12mm thick ASTM A36 steel plate weld overlaid by hardfacing electrode HV-450 of 3.2 mm diameter at various welding currents, 90, 110, and 130 amperes, respectively. The investigation was conducted by using optical microscopy, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and hardness test on the hardfacing overlay. The results showed the hardness of the hardfacing overlay is higher than the base metal, indicating higher strength of the weld overlay. From the three welding currents applied, the highest hardness in the weld overlay is obtained at the lowest current.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.