Abstract
In order to investigate the effect of americium addition in MOX fuel on the irradiation behavior, the ‘Am-1’ program is being conducted in the experimental fast reactor Joyo. The Am-1 program consists of two short-term irradiation tests of 10min and 24h irradiations and a steady-state irradiation test. The short-term irradiation tests were successfully completed and the post irradiation examinations (PIEs) are in progress. This paper reports on the results of PIEs for Am-containing MOX fuel irradiated for 10min. MOX fuel pellets containing 3% or 5% Am were fabricated in a shielded air-tight hot cell using a remote handling technique. The oxygen to metal ratio (O/M) of these fuel pellets was 1.98. They were irradiated at peak linear heating rate of about 43kWm−1. Focus was being placed on migration behavior of Am during the irradiation. The ceramography results showed that structural changes such as lenticular pores and a central void occurred early, within the brief 10min of irradiation. The results of electron probe microanalysis revealed that the concentration of Am increased in the vicinity of the central void.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.