Abstract

A microstructural and mechanical properties study was conducted to investigate the effect of the curing conditions on the final properties of self-compacting concrete. Two different curing conditions were considered simulating the summer conditions in coastal (20°C and 70% relative humidity, RH) and central (cycles of 40°C) zones in Spain. Different microstructural and mechanical parameters were measured to study the hydration using different techniques: Micro-Raman spectroscopy, nuclear magnetic resonance, compressive strength and ultrasonic testing. After 7days of hydration the central conditions produce samples with higher hydration degree than coastal conditions, but after 28days of curing, the hydration degree was very similar in both curing conditions. This high hydration degree after 7days conducted to a decline or stabilization in compressive strength at long curing times. The mean chain length of the C-S-H gel formed in the studied concrete was quite high comparing with other works since more Al was incorporated in the C-S-H gel. It was also obtained that for high temperatures after 7days of curing all microstructural and mechanical parameters were quite stable meaning that high temperatures accelerate the hydration of the samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call