Abstract

The micromechanical fracture behavior of Si [100] was investigated as a function of temperature in the scanning electron microscope with a nanoindenter. A gradual increase in KC was observed with temperature, in contrast to sharp transitions reported earlier for macro-Si. A transition in cracking mechanism via crack branching occurs at ∼300 °C accompanied by multiple load drops. This reveals that onset of small-scale plasticity plays an important role in the brittle-to-ductile transition of miniaturized Si.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call