Abstract

The spatiotemporal resolution of diagnostic X-ray images obtained with rotating-anode X-ray tubes has remained limited as the development of rigid, high-performance target materials has slowed down. However, novel imaging techniques using finer detector pixels and orthovolt cancer therapy employing narrow X-ray focal spots demand improved output from brilliant keV X-ray sources. Since its advent in 1929, rotating-anode technology has become the greatest bottleneck to improvement. To overcome this limitation, the current authors have devised a novel X-ray generation technology based on tungsten microparticle targets. The current study investigated a hybrid solution of a stream of fast tungsten microparticles and a rotating anode to both harvest the benefits of the improved performance of the new solution and to reuse known technology. The rotating anode captures energy that may pass a partially opaque microparticle stream and thereby contributes to X-ray generation. With reference to fast-rotating anodes and a highly appreciated small focal spot of a standardized size of 0.3 for an 8° target angle (physical: 0.45 mm × 4.67 mm), we calculated a potential output gain of at least 85% for non-melting microparticles and of 124% if melting is envisioned. Microparticle charging can be remediated by electron backscattering and electron field emission. The adoption of such a solution enables substantially improved image resolution.