Abstract
The use of titanium and its alloys (Ti-6Al-4V) for oral surgery has increased dramatically in recent years. Ti is a stable biocompatible metal suitable for oral applications and it has been used for endosseous subperiosteal implants and miniplate fixation for more than 25 years. Dental implants are typically made of Ti or Ti alloys. The alloys are potentially toxic due to release of vanadium and aluminum. We tested the possible genotoxicity of Ti alloy endosseous implants and miniplates on the oral mucosal tissues of two groups of patients: 17 patients receiving Ti miniplate and screw fixation, and 37 endosseous dental implant placement patients. Preoperative and postoperative mucogingival cell samples were collected. Genotoxicity was assessed by the micronucleus assay (MN). There were slight but not statistically significant increases in the frequencies of MN (p=0.087 and p=0.047) post-operation in both groups. In summary, neither of the applications showed genotoxicity in the oral epithelial cells of patients.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Mutation Research/Genetic Toxicology and Environmental Mutagenesis
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.