Abstract
ABSTRACTThis paper describes the fabrication and calibration of micromachined shear stress sensors intended for characterization of the local pad-wafer contact forces present during chemical-mechanical polishing. Sensors consist of arrays of microfabricated poly-dimethyl-siloxane (PDMS) posts and are able to measure forces ranging from 2 to 200 μN. The posts are 100 μm high and have diameters of 40-100 μm. Calibrated post deflection sensitivities are linear and lie between 0.2 μm/μN and 1.3μm/μN. Sensor design, fabrication, and calibration are detailed. Feasibility is established for sensor integration into a CMP scale model test setup, including an optical viewing method for observing post deflection during polishing. Initial micrographs of post deflection during polishing do not yet have sufficient resolution to determine the microscale forces during polishing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.