Abstract
A micromethod for the determination of the amine oxide group in organic compounds is described. It is based on the reduction with an excess of titanium(III) reagent at pH 5–6, which is quantitative at room temperature within 5 min. Excess titanium(III) is back-titrated with iron(III) solution. The accuracy is about ±0.5%. Amine oxide and nitro groups are determined together. An assembly for the preparation and storage of the titanium(III) solution is also described.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.