The present paper reports results of monotonic tensile and of fatigue testing of an aligned monofilament composite SiC–Al. Macroscopic measures of damage (changes in unloading compliance and in unrecovered strain) correlate with noninvasive X-ray microCT (microtomography) quantification of microstructure (alteration of fibre separation, fibre misorientation relative to the load axis and amount of fibre fracture). Monotonic loading beyond yield (188 MPa) alters fibre arrangement and reduces fibre misorientation. Fracture of fibre carbon cores begins at 828 MPa and increases rapidly with rising stress concomitant with marked unloading modulus decreases and permanent strain increases. Fatigue at 621 MPa produces gradually increasing modulus and unrecovered strain with no evidence of fibre damage. At low cycles, the modulus, permanent strain and fraction of fractured C cores increase while fibre misorientation decreases; above 16 cycles, modulus decreases with gradual increases in the other quantities. Fracture in SiC could only be observed after the specimen broke.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.