Abstract

A microconcentric nebuliser was evaluated for the analysis of small volumes of sample. An optimum set of conditions was obtained for a range of analytes by optimisation of the nebuliser gas flow rate. The technique was evaluated by accurate analysis of reference material NIES No. 5 using just 100 µl of sample. Recoveries between 95 and 106% were obtained for all the elements determined. The technique was then applied to the analysis of biological samples and to the analysis of a peptide, with multi-element analysis on less than 100 µl of sample. Acceptable reproducibility and precision were obtained for both sample types. Recoveries between 95 and 118% were obtained for the biological samples and between 72 and 104% for the peptide samples. The microconcentric nebuliser permits a significant decrease in sample volume for multi-element analysis without loss of accuracy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.