Abstract

The efficacy of cold storage of raw, bagged, boxed beef was assessed microbiologically at a high-line-speed abattoir (270 carcasses per h). At the time of this study, plant management was in the process of creating a hazard analysis critical control point plan for all processes. Aerobic bacteria, coliforms, and type 1 Escherichia coli were enumerated (5 by 5-cm excision samples, hydrophobic grid membrane filter technology) before and after cold storage of this final product produced at six fabrication tables. In addition, the temperature-function integration technique (TFIT) was used to calculate the potential number of generations of E. coli during the first 24 or 48 h of storage of the boxed beef. Based on the temperature histories (total of 60 boxes, resulting from 12 product cuts, five boxes from each of two fabrication tables on each of 6 sampling days, and six types of fabrication tables), TFIT did not predict any growth of E. coli (with or without lag) for the test period. This was verified by E. coli mean log10 values of 0.65 to 0.42 cm2 (P > 0.05) determined by culture before and after the cooling process, respectively. Counts of aerobic bacteria and coliforms were significantly reduced (P < 0.001 and P < 0.05, respectively) during the initial period of the cooling process. There were significant microbiological differences (P < 0.05) between table-cut units.