Abstract
The aim of the study was to evaluate the impact of manual cleaning and manual cleaning followed by Ultraviolet-C disinfection on the colony forming units of bacteria retrievable from equipment and surfaces within clinic rooms following a CF outpatient encounter. While UV disinfection has proven to be effective within general healthcare settings, it has not been evaluated in a CF centre.Microbiological sampling was performed following outpatient encounters involving 11 adult patients with CF and chronic infection with P.aeruginosa, MRSA or E. coli ESBL.The results of this study suggest that manual cleaning followed by UV-C disinfection is more effective than manual cleaning alone at reducing environmental contamination within a CF clinic and that UV-C isinfection is likely to reduce the risk of fomite transmission in the CF outpatient setting.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.