Abstract

The microbiological quality of filtered water in a commercial water filter system (Brita) was tested in households and in two laboratories. In 24 of 34 filters used in households, bacterial counts increased in the filtered water up to 6,000 cfu/ml. In 4 of 6 filters tested in the laboratory, bacterial counts in the fresh filtrate were higher than in tap water after approximately one week of use both at room temperature and at 4 degrees C, suggesting growth or biofilm formation in the filter material. In some cases colony counts in the filtered water were 10,000 times those in tap water. The filter material of 5 of 13 new commercial filters was contaminated with bacteria or moulds. National or international regulatory agencies should ensure that water filters marketed for domestic use do not allow deterioration in the microbiological quality of drinking water.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.