Abstract

To evaluate factory-sealed containers of three different commercially available irreversible hydrocolloid impression materials for their microbial contamination and the type of microorganisms present. Thirty-six measured samples were taken of each brand and placed on chocolate agar plates or in thioglycolate broth tubes and were incubated along with appropriate parallel controls. After incubation, colonies were enumerated and identified using standard microbiological methods. The three brands contained viable microorganisms in 90% of the samples. Samples from the top, middle and bottom layers had approximately equal contamination frequencies. The concentration of organism varied from 25 to 74 CFUs per gram of contaminated sample. The samples contained viable microorganism which may be potentially dangerous to immunocompromised patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.