Abstract

The benefits of regular exercise include improved physical and mental health. The school gym is a particular micro-environment where students perform intensive physical training. The question is if there is an increased risk of microbiological contamination. This preliminary work studied the exposure of students to bacterial aerosol (BA) in a highschool gym located in an urban area of Southern Poland. A sampling of BA was undertaken with an Andersen six-stage impactor (ANDI). BA was identified using API (analytical profile index) tests. The BA concentrations were expressed as Colony Forming Units (CFU) per cubic metre of air. The results showed that before gym classes (BGC), the concentration of BA was 4.20 × 102 ± 49.19 CFU/m3, while during gym classes (DGC), the level of BA more than doubled (8.75 × 102 ± 121.39 CFU/m3). There was also an increase in the respirable fraction of BA (particles less than 3.3 µm). Before the start of the sports activities, respirable fraction accounted for 30% of the BA, while during physical education classes, this share increased to over 80%. Identification of BA species showed that the dominant group of bacteria in the indoor air of the gym BGC was Gram-positive rods (61%) and for DGC it was Gram-positive cocci (81%). We detected that one bacteria strain (Corynebacterium striatum) was classified into risk group 2 (RG2) according to Directive 2000/54/EC. Additionally, multi-antibiotic resistance (MAR) showed that among the isolated airborne bacteria, the highest antibiotic resistance was demonstrated by Staphylococcus epidermis (isolated DGC) and Pseudomonas sp. (isolated BGC). The quantitative and qualitative information on microbiological air quality (MIAQ) in the school gym indicates that the actions to improve indoor physical activity spaces are recommended.

Highlights

  • According to available studies on indoor air quality (IAQ), it was found that both air pollution and physical conditions have a negative impact on the health of building residents [1,2,3,4,5,6,7,8,9].Previous studies conducted in educational buildings showed that poor microbiological indoor air quality (MIAQ) in classrooms exerts a negative effect on students’ learning performance [10]

  • The objectives of this study are: (a) to assess bacterial aerosol (BA) air quality in the gymnastic hall of a highschool building located in the urban area of Southern Poland, (b) to determine the concentration and BA particle size distribution in the gymnastic hall before gym classes (BGC), during gym classes (DGC) and in the outdoor air (OUT), (c) to identify isolated strains of bacteria BGC and DGC and (d) to determine the antibiotic resistance of isolated strains of BA

  • The BA concentration indoors was nearly four times the concentration outdoors. These results indicate that the source of the increased concentration DGC is due to the presence of students, because humans are the main source of bacterial emission indoors, and are confirmed with the data available in the literature [8,29,37]

Read more

Summary

Introduction

According to available studies on indoor air quality (IAQ), it was found that both air pollution and physical conditions (including temperature, humidity and inefficient ventilation) have a negative impact on the health of building residents [1,2,3,4,5,6,7,8,9]. Previous studies conducted in educational buildings showed that poor microbiological indoor air quality (MIAQ) in classrooms exerts a negative effect on students’ learning performance [10]. Poor air quality has been shown to increase absenteeism and increase the risk of asthma and other health-related issues [11,12]. About 1% of school-age children in Poland suffer from chronic respiratory diseases [13]. There are 8000 secondary schools in Poland, with 13,360 students.

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call