Abstract
Inactivation of Escherichia coli has been successfully performed by the utilization of impulse voltage waveform. The process involves in microbial inactivation is pulsed electric field (PEF) treatment. PEF utilizes short-duration high-voltage pulses for microbial inactivation by the process of electroporation. Inactivation rate was measured against peak electric field, number of applied pulses, and energy input to unit volume of liquid. Two different electrode configuration spherical–spherical and parallel-plate electrode systems were used. The results indicate that parallel-plate electrode system results in better inactivation rate than spherical electrode system. With applied electric field of 24 kV/cm and 20 pulses, six log reductions were achieved in parallel-plate electrode system indicating that inactivation rate is strongly dependent on electrode configuration, peak electric field, and applied pulses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.