Abstract

In this study, we measured microbial growth and endotoxin production in the intravenous anesthetic propofol using 10 different microbial strains; 6 isolated from outbreak cases and 4 from laboratory stock cultures. In each trial, endotoxin-free glass tubes containing 10 ml propofol were inoculated with 10(0)-10(3) CFU/ml of the test organism and incubated at 30 degrees C for 72 hours. In May and June 1990, the Centers for Disease Control received reports of 5 outbreaks in 5 states of postsurgical patient infections and/or pyrogenic reactions. Epidemiologic and laboratory investigations implicated extrinsic contamination of an intravenous anesthetic, propofol, as the probable source of these outbreaks. After 24 hours, 9 of the 10 cultures increased in viable counts by 3 to 6 logs. At least 1 ng/ml of endotoxin was produced within 24 hours by Escherichia coli, Enterobacter cloacae, and Acinetobacter calcoaceticus subspecies anitratus. Propofol can support rapid microbial growth and endotoxin production. To avoid infectious complications, scrupulous aseptic technique should be used when preparing or administering this anesthetic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.