Abstract

The use of microbial ATP bioluminescence was evaluated as a means to rapidly detect gross microbial contamination from feces on bovine-carcass surface tissue (BCT). Microbial ATP was selectively distinguished from nonmicrobial ATP by the assay procedure used. Regression analyses of microbial ATP and viable count scatterplots showed lean and adipose BCT artificially contaminated with bovine feces had the same regression line parameters (P < 0.05), and therefore, the microbial ATP responses were similar for both tissue types. Correlation coefficients (r) of these regression lines were >0.90 for both tissue types. Results indicated that swab samples can be held at 5°C for up to 6 h without compromising microbial ATP bioluminescence assay results. The microbial ATP bioluminescence assay shows potential for use as a means to rapidly detect fecal contamination on red meat carcasses and to gauge decontamination effectiveness and hence could monitor critical control points in a processing-plant HACCP plan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.