Abstract

A carrier-mediated supported liquid membrane micro-extraction using single hollow fiber membrane suitable for the determination of the herbicide glyphosate and its main metabolite aminomethylphosphonic acid in water is reported. A solution of 0.20 M Aliquat-336, a cationic carrier, in di- n-hexyl ether was selected as the supported liquid. A 20 μL of 1.0 M potassium chloride as the acceptor phase was filled in the membrane lumen. The membrane was immersed in a 20 mL of pH 9.0 sample solution. After 60-min extraction, the acceptor phase was analyzed by high-performance liquid chromatography with post-column derivatization. The enrichment factors were found to be 853 and 136 for glyphosate and aminomethylphosphonic acid, respectively. The method detection limits are 0.22 μg/L for glyphosate and 3.40 μg/L for aminomethylphosphonic acid. The procedure was validated and showed good accuracy and precision over a large linear dynamic range. The validated method was tested for the analysis of both analytes in spiked groundwater with good success.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.