Abstract

Abstract Background Catheter ablation of atrial fibrillation (AF) is associated with risks of silent cerebral events. However, the timing of intraprocedural micro-embolic events or differences between open-irrigated radiofrequency (RF) and cryoballoon (Cryo) ablation are unclear. Newly developed real-time carotid artery Doppler is a simple non-invasive method to detect micro-embolic signals (MESs) during ablation. Objective We investigated the timing of detecting MESs during RF and Cryo ablation of AF. Methods During the first pulmonary vein isolation (PVI) session of AF, MESs were monitored by real-time carotid artery Doppler monitoring throughout the procedure. The MES counts were collected and evaluated separately during the different steps of the procedure (Figure). Results Thirty-three AF patients (RF/Cryo: 22/11 cases, 9 females, 69.5±11.6 y.o) were included. PVI was successfully accomplished in all patients with no major complications. The MES count was significantly greater in the RF group than Cryo group (table). In both groups, left atrial (LA) access (interatrial puncture) and sheaths insertion to the LA generated a significant number of MESs (RF: 1690 of 9116 MESs [18.5% of the total MESs], Cryo: 793 of 2285 MESs [34.7%]). In the RF group, MESs were observed incessantly during PVI (Figure). The LA dwell time was significantly longer in the RF group than Cryo group (table). In the RF group, the MES count was significantly greater in the longer LA dwell time group (LA dwell time >130min) than the shorter group (464.2±179.7 vs 302.6±138.2: P=0.049). During the cryo-applications in the Cryo group, the MESs were greatest during the first cryoballoon application (625 of 2285 MESs [27.4%]). Conclusions There were more MESs during RF ablation than cryoablation. MESs were recorded during a variety of steps throughout the procedure. In the RF group, most of MESs were recorded incessantly during radiofrequency ablation and greater number of MESs were recorded in patients with longer LA dwell time. In the Cryo group, most of MESs occurred during phases with a high probability of gaseous emboli. Funding Acknowledgement Type of funding source: None

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.