Abstract

A variety of defects in continuous steel strip may result in a ccidents. Traditional MFL (Magnetic flux leakage) testing method can lead to large blind area because steel str ip is too broad to be rotated. A new MFL testing method that can inspect omni-directional cracks in steel strip is introduc ed in this paper. This method is characterized basically by t he deep saturation state of steel strip generated. The property of i nspection is investigated using 3-D finite element method. W aveform configurations of the experimental results agree with that o f the theoretical predictions. Automatic inspecting equip ment has been developed based on the new MFL method principle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.