Abstract

While pressure-sensitive paint (PSP) is evolving into a viable alternative to conventional pressure taps for surface pressure measurements, the inherent temperature-sensitivity of the coating's fluorescence intensity is a prominent drawback. Unless the PSP is applied to a temporallyand spatially-isothermal surface, this inherent temperature-sensitivity effect severely limits the accuracy of the two-dimensional pressure distribution obtained from the coating. In this study, the pressureand temperature-sensitivity effects of three PSPs and two temperature-sensitive paints (TSPs) are evaluated over pressure and temperature ranges found in many compressible flow experiments. In addition, four PSP data reduction methods are compared by applying PSP to a transverse-jet-incrossflow experiment. Each data reduction method encompasses a different degree of temperature correction. Conventional pressure taps in the tunnel wall are used to evaluate the accuracy of each method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.